Online Demo
Request More Information
Visit Our Metrology Lab
Download Mudcats Brochure
 

 

 

 

Datasheet Designer

Quickly and easily create datasheets that are consistent in form and function. Let the integrated tolerance calculator use manufacturer's specifications to automatically create test points, calculate tolerances, embed specification data and format the data. Build your own datasheets using MudCats' built-in Wizards or create your own Wizards with the Wizard Workshop. MudCats Datasheet Designer eliminates time-consuming and error-prone manual datasheet construction, increasing productivity.

Automatic EMU, TAR/TUR, Guard Band tolerances

MudCats automatically calculates Estimated Measurement Uncertainty (EMU), Test Accuracy Ratio/Test Uncertainty Ratio (TAR/TUR), and Guard Band Tolerances from specifications embedded into datasheets and SpecTrack specsheet data. More than a simple automation tool, this capability also facilitates the automatic implementation of guard banding and conformance testing. Conformance test rules and formats are fully configurable. These innovative capabilities dramatically reduce the required time and skill level to accomplish statistically advanced calibrations.

Units of Measure Interpreter/ Converter

MudCats' intelligent units converter revolutionizes datasheet design, uncertainty calculations and calibration data collection by automatically interpreting and converting units of measure between your Standard(s) and the unit under test. Automatic EMU, TAR/TUR, Guard Band tolerances and calculations facilitate rapid implementation of conformance testing, and conversion errors are virtually eliminated, guaranteeing faster and more reliable calibrations.

Custom Tolerance Calculator

In a perfect world, all tolerance calculations would consist of simple, straightforward components, such as "% IV", "% FS", "Fixed Value" or "dB". Unfortunately, we don't live in a perfect world. Fortunately, MudCats incorporates a custom calculator design wizard to deal with these not so simple, complex tolerance statements. Our Custom Tolerance Calculator is used to calculate tolerances based on non-standard specifications. Build a library of custom calculators to meet your specific and complex specification requirements.

Multi-Channel Data Collection

Calibrate up to 8 instruments at one time utilizing MudCats' exclusive multi-channel data collection technology. Each channel displays "As Found" and "As Left" data, and automatically calculates percent of tolerance and out-of-tolerance conditions independently. Individual channels can be edited, saved and printed independently or collectively. Multi-channel data collection results in significant increases in productivity.

Automated Calibration

Not your over-the-counter style ATE, MudCats Automated Calibration commands are easily created and executed, with no instrument drivers required. Create your automation using parameterized commands. Wizards assist you in the configuration of the command's parameters. Add automation where you want, when you want. Automation can be a combination of text instructions, graphics, GPIB (IEEE-488) or RS-232 instrument interface commands, variable inputs, and math equations. You may automate an entire datasheet or just a few test points. Combine instrument-specific automation with multi-channel calibrations and your production soars.

Certificates and Data Reports

The end result of all the calibration data collection, calculations, quality control & training is the Calibration Certificate and associated Calibration Report. MudCats is the only commercially available program designed just for the calibration laboratory that aids not just data collection but also with the final product itself. The MudCats Suite of tools provides a Calibration Certificate generator that will not only generate a professional high-quality Calibration Certificate, but will also maintain it and all associated data in one archived database. This is just one of the many ways that MudCats fulfills not just your laboratory needs, but all of your compliance requirements, too.

Revision Control

Calibration datasheets, measurement results and subsequent revisions are maintained and controlled through MudCats' exclusive Revision Control process, in accordance with ANSI/ISO/IEC 17025 Section 4.3 Document Control. Datasheets and calibration results are electronically approved and time/date stamped for approval by the authorized user. Previous datasheet or calibration results are inactivated, yet maintained in the system for historical documentation archiving.

Portable Field Calibrations

IIn spite of technological advancement, nearly every calibration lab struggles with taking information from the lab into the field. MudCats conquers this challenge with laptop capabilities that make MudCats fully mobile and portable. MudCats ProRemote option provides complete synchronization between the master system and your notebook computers. The synchronization system automatically updates datasheets to the newest revision and uploads all of the calibration results with a click of a button. Take your lab to the field with ProRemote.

On-line Datasheet Catalogue

MudCats was designed by Metrologists for Metrologists. It is in use every day by the lab that designed it; one of the largest and most comprehensive calibration laboratories in the country. Your support agreement entitles you to pull from our on-line library of datasheets in a variety of disciplines. Already populated with thousands of datasheets and scripts, this library is growing daily. For the first time ever, processes and documents are available, ready-made, that meet the needs of all the most demanding industries - aerospace, pharmaceutical, nuclear and high tech manufacturing. MudCats is not just a product; it truly is your partner in excellence.

 

Contact Us | © 2002 Edison ESI - All Rights Reserved